Flame Retardant Solutions

Tricel Flame Retardant Honeycomb

Flame Retardant Honeycomb

UL 94HBF testing shows the successful retardation of the Tricel Honeycomb substrate treated with the PyroTech Flame retardant solution.

Applications for Flame Retardant Honeycomb

Numerous applications can benefit from our flame retardant honeycomb.

  • Doors
  • Furniture
  • Building Panels
  • Acoustics
  • Filtration
  • And Many More Applications

Steiner Tunnel Test

UL 723 Results
Test Number 1
Test Code NTN01202604
Sample Description Honeycomb Core
CFS
Calculated Flame Spread
0.00
FSI
Flame Spread Index
0
CSD
Calculated Smoke Developed
34.0
SDI
Smoke Developed Index
35

The test determines the Surface Burning Characteristics of the material, specifically the flame spread and smoke developed indices when exposed to fire.

The product meets criteria for Class A, B, and C fire ratings.

Class Flame Spread Index (FSI) Smoke Developed Index (SDI)
Class A (Class I) 0 – 25 0 – 450
Class B (Class II) 26 – 75 0 – 450
Class C (Class III) 76 – 200 0 – 450